| Performance Specification | ||||||||||||
| System Model | GB-F72 | GB-F90 | GB-F108 | GB-F126 | GB-F144 | GB-F162 | GB-F180 | GB-F198 | GB-F216 | GB-F234 | GB-F252 | |
| Battery Type | LiFePO4 | |||||||||||
| Capacity(Ah) | 314 | |||||||||||
| Battery Module Qty In Series(Optional) | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | |
| System Nominal Energy (kWh) | 72.34 | 90.43 | 108.51 | 126.6 | 144.69 | 162.77 | 180.8 | 198.95 | 217.03 | 235.12 | 253.2 | |
| System Nominal Voltage (V) | 230.4 | 288 | 345.6 | 403.2 | 460.8 | 518.4 | 576 | 633.6 | 691.2 | 748.8 | 806.4 | |
| System Operating Voltage(V) | 187.2~262.8 | 234~328.5 | 280.8~394.2 | 327.6~459.9 | 374.4~525.6 | 421.2~591.3 | 468~657 | 514.8~722.7 | 561.6~788.4 | 608.4~854.1 | 655.2~919.8 | |
| Rated DC Power (kW) | 36.1728 | 45.216 | 54.2592 | 63.3024 | 72.3456 | 81.3888 | 90.432 | 99.4752 | 108.5184 | 117.5616 | 126.6048 | |
| Charge/Discharge Current (A)[1] | Recommend | 157/157 | ||||||||||
| Max. Continuous | 200/200 | |||||||||||
| Peak | 295@25℃,15s | |||||||||||
| Recommend Depth Of Discharge[2] | 100% | |||||||||||
| Cycle Life[3] | ≥8000 | |||||||||||
| System General Data | ||||||||||||
| Communication | CAN2.0,RS485,Bluetooth | |||||||||||
| System Ingress Protection Rating | IP66 | |||||||||||
| Display | LCD | |||||||||||
| Scalability | Max.16 Clusters In Parallel | |||||||||||
| Installation Method | Floor Mount(Modular Stack) | |||||||||||
| Fire Suppression | Aerosol and Explosion Relief Valve | |||||||||||
| Cooling Method | Natural Air Cooling | |||||||||||
| Operating Temperature(℃)[4] | Charge: 0~55 ; Discahrge: -20~55 / Build-in Heating Function: -25-55(Optional) | |||||||||||
| Storage Temperature(℃) | -30~60 | |||||||||||
| Humidity(%) | 0 % ~ 100 % RH, non-condensing | |||||||||||
| Noise(dB)[5] | <65@1m | |||||||||||
| Altitude(m) | ≤3000 | |||||||||||
| Warranty Period[6] | 10 Years | |||||||||||
| Compliance Standard | IEC 62619, IEC63056, UN38.3, IEC 62477, IEC 62040, IEC 61000-6-1/3, VDE-2510-50, IEC 62933-5-2, UL 9540A | |||||||||||
| Note: [1] The current is affected by temperature and SOC. [2] Adjustable as required. [3] Test conditions : 0.2C Charging & Discharging, 25°C±2°C. [4] Restricted by LFP cell chemistry: ambient temperature > -20°C required for restart after shutdown. [5] Noise level is tested based on the rated operating conditions (25 °C ambient temperature, 0.5C charge/discharge rate). [6] Conditions apply, refer to Deye Warranty Letter. |
||||||||||||
We look forward to long-term friendly cooperation with you!
"*" indicates required fields