| Model | GE-F112-BC-2-A3 | GE-F128-BC-2-A3 |
|---|---|---|
| Main Parameters | ||
| Cell Type | LiFePO₄ | |
| Module Capacity (Ah) | 314 | |
| Module Nominal Voltage (Vdc) | 51.2 | |
| Module Energy (kWh) | 16.07 | |
| Module Qty In Series | 7 | 8 |
| System Nominal Energy (kWh) | 112 | 128 |
| System Usable Energy (kWh)*1 | 112 | 128 |
| System Nominal Voltage (Vdc) | 358.4 | 409.6 |
| System Operating Voltage (Vdc) | 280-408.8 | 320-467.2 |
| Rated DC Power (kW) | 56 | 64 |
| Charge/Discharge Max. Continuous Current(A)*2 | 180 | |
| Peak discharge@15s/25±2℃ | 285 | |
| Other Parameters | ||
| Fire Protection System | Aerosol and Water fire interface | |
| Cooling Method | Smart Air Cooling | |
| Communication Port | CAN, RS485 | |
| Communication protocol | CAN2.0, Modbus, TCP/IP | |
| Operating Temperature(℃)*3 | -30-55 | |
| Recommend Storage Temperature(℃) | 0-55 | |
| Humidity | 5% – 95%RH (No Condensing) | |
| Altitude | 3000m | |
| IP Protection | IP55 | |
| Anti Corrosion Level | C4-M | |
| Dimension(W x D x H mm) | 998 x 1240 x 2400 | |
| Weight(kg) | 1595 | 1700 |
| Installation Location | Floor mount | |
| Cycle Life | ≥8000 (25±2℃ 0.5P EOL70%) | |
| Warranty | 10 years | |
| Certification | UN38.3, IEC, CE, VDE, ROHS, REACH | |
| Model | GE-F176-BC-2-A3 | GE-F208-BC-2-A3 | GE-F240-BC-2-A3 |
|---|---|---|---|
| Main Parameters | |||
| Cell Type | LiFePO₄ | ||
| Module Capacity (Ah) | 314 | ||
| Module Nominal Voltage (Vdc) | 51.2 | ||
| Module Energy (kWh) | 16.07 | ||
| Module Qty In Series | 11 | 13 | 15 |
| System Nominal Energy (kWh) | 176 | 208 | 241 |
| System Usable Energy (kWh)*1 | 176 | 208 | 241 |
| System Nominal Voltage (Vdc) | 563.2 | 665.6 | 768 |
| System Operating Voltage (Vdc) | 440-642.4 | 520-759.2 | 600-876 |
| Rated DC Power (kW) | 88 | 104 | 121 |
| Charge/Discharge Max. Continuous Current(A)*2 | 180 | ||
| Peak discharge@15s/25±2℃ | 285 | ||
| Other Parameters | |||
| Fire Protection System | Aerosol and Water fire interface CO gas detection, Active exhaust and Explosion venting | ||
| Cooling Method | Smart Air Cooling | ||
| Communication Port | CAN, RS485 | ||
| Communication protocol | CAN2.0, Modbus, TCP/IP | ||
| Operating Temperature(℃)*3 | -30-55 | ||
| Recommend Storage Temperature(℃) | 0-55 | ||
| Humidity | 5% – 95%RH (No Condensing) | ||
| Altitude | 3000m | ||
| IP Protection | IP55 | ||
| Anti Corrosion Level | C4-M | ||
| Dimension(W x D x H mm) | 1300 x 1240 x 2400 | ||
| Weight(kg) | 2080 | 2290 | 2500 |
| Installation Location | Floor mount | ||
| Cycle Life | ≥8000 (25±2℃ 0.5P EOL70%) | ||
| Warranty | 10 years | ||